WBL 120 |
|
ARTICLE NUMBER
|
60110120
|
WBL-120 Battery Link, 9 -35V, 120A cont., 180A maximal
|
TECHNICAL SPECIFICATIONS
|
Dimensions ( l x b x h )
|
46 x 80 x 46 mm
|
Weight
|
125 gram
|
Continuous rating
|
120 A
|
Cranking rating ( 10 sec ) / inrush rating
|
180 A
|
Input voltage
|
9-35 VDC
|
Operation temperature
|
-40 to 65 °C
|
Maximum voltage drop
|
0.5 VDC ( delay time before disconnect: approx. 10 sec. )
|
Maximum allowed voltage difference
|
8.0 VDC
|
AUTOMATIC MODE
|
Switch on voltage ( minimum )
|
> 13 V @ 12 V / > 26 V @ 24 V
|
Switch on delay time
|
5 sec.
|
Switch on voltage ( maximum )
|
15.0 V @ 12 V / 30.0 V @ 24 V
|
Automatic drop off voltage
|
< 12,75 V @ 12 V / < 25,5 V @ 24 V
|
DC DRAIN
|
OFF mode ( solenoid not activated )
|
1.0 mA @ 12 V / 1.1 mA @ 24 V
|
ON mode ( inrush current )
|
0,5 A @ 12 V / 40 mA @ 24 V
|
ON mode ( solenoid is activated )
|
50 mA @ 12 V / 40 mA @ 24 V
|
STATUS LED
|
On
|
Solenoid is activated ( ON mode )
|
Slow blinking ( 0.5 Hz )
|
Delay time before solenoid will switch on
|
Fast blinking ( 2.5 Hz )
|
Alarm: Solenoid is not activated as voltage difference is either too high ( > 8.0 VDC ) in OFF mode or
|
|
|
|
|
|
|
|
|