WP-BC Supreme 12 V - 100 A |
|
ARTICLE NUMBER
|
61112310
|
WP-BC Supreme 12 V - 100 A
|
CHARGER OUTPUT
|
Output Current (Maximum)
|
20 A
|
Output Voltage Bulk
|
28.4 - 31 V
|
Output Voltage Float
|
26.8 - 27.6 V
|
Output Voltage Equalize
|
32.0 V
|
Charging Control
|
3-step (Bulk/Absorption/Float)
|
DC Output Bank
|
3
|
Selectable Battery Type
|
GEL, AGM, WET, Lithium
|
Back Current
|
< 2 mA
|
CHARGER INPUT
|
AC Input Voltage (Nominal)
|
100, 120, 220, 230, 240 VAC
|
AC Input Operating Range
|
90 - 265 VAC
|
AC Input Frequency Range
|
47 - 63 Hz
|
Power Consumption (Full Load)
|
700 W
|
Power Factor Correction
|
Yes
|
Charger Efficiency
|
> 82%
|
PROTECTION AND FEATURES
|
Reverse Battery
|
Yes, unit shutdown
|
Over Charge
|
Yes, unit shutdown
|
Over Heating
|
Yes, unit de-rated and shutdown
|
Output Short Circuit
|
Yes, unit shutdown
|
DC Fuse
|
2*20A, 32V
|
Cooling
|
Force air ventilation
|
Temperature Setting
|
Hot, Normal, Cold (no sensor connected)
|
Battery Temperature Sensor Port
|
RJ12 (for use with optional Battery Temperature Sensor)
|
Digital Display Port
|
RJ12 (for use with optional Remote Display Panel ACRM1202)
|
DISPLAY
|
LCD Display (with back lighting)
|
Charging status, Battery Voltage
|
Warning and Fault Code
|
A01, E01-09
|
AC INPUT AND DC OUTPUT CONNECTION
|
AC Input Connection
|
Hardwire or AC Cord
|
DC Output Connection
|
Heavy Duty Studs (3 banks)
|
DC Output Ground
|
Single Heavy Duty Common Ground Stud
|
ENVIRONMENTAL AND OPERATING TEMPERATURE
|
Storage Range
|
-40° to 70° C (-40° to 158° F)
|
Operating Range
|
-20° to 60° C (-4° to 140° F)
|
Humidity
|
5-95%, RH non-condensing
|
Ingress Protection
|
IP32
|
DIMENSIONS AND WEIGHT
|
Dimensions
|
236 x 425 x 102.7 mm (9.3 x 16.7 x 4’)
|
Weight
|
at request
|
|
|
|
|
|
|
|
|