WP-BC Supreme 24 V - 30 A |
|
ARTICLE NUMBER
|
61124303
|
WP-BC Supreme 24 V - 30 A - 3 outputs
|
CHARGER OUTPUT
|
Output Current (Maximum)
|
30 A
|
Output Voltage Bulk
|
28.4 - 31 V
|
Output Voltage Float
|
26.8 - 27.6 V
|
Output Voltage Equalize
|
32.0 V
|
Charging Control
|
3-step (Bulk/Absorption/Float)
|
DC Output Bank
|
3
|
Selectable Battery Type
|
GEL, AGM, WET, Lithium
|
Back Current
|
< 2 mA
|
CHARGER INPUT
|
AC Input Voltage (Nominal)
|
100, 120, 220, 230, 240 VAC
|
AC Input Operating Range
|
90 - 265 VAC
|
AC Input Frequency Range
|
47 - 63 Hz
|
Power Consumption (Full Load)
|
1050 W
|
Power Factor Correction
|
Yes
|
Charger Efficiency
|
> 82%
|
PROTECTION AND FEATURES
|
Reverse Battery
|
Yes, unit shutdown
|
Over Charge
|
Yes, unit shutdown
|
Over Heating
|
Yes, unit de-rated and shutdown
|
Output Short Circuit
|
Yes, unit shutdown
|
DC Fuse
|
2*20 A, 32 V
|
Cooling
|
Force air ventilation
|
Temperature Setting
|
Hot, Normal, Cold (no sensor connected)
|
Battery Temperature Sensor
|
Yes included with 1.5mtr cable
|
Battery Temperature Sensor Port
|
RJ12 (battery temp. sensor use)
|
Digital Display Port
|
RJ12 (optional display panel use)
|
DISPLAY
|
LCD Display (with back lighting)
|
Charging status, Battery Voltage
|
Warning and Fault Code
|
A01-02, E01-09
|
AC INPUT AND DC OUTPUT CONNECTION
|
AC Input Connection
|
Hardwire or AC Cord
|
DC Output Connection
|
Heavy Duty Studs (3 banks)
|
DC Output Ground
|
Single Heavy Duty Common Ground Stud
|
ENVIRONMENTAL AND OPERATING TEMPERATURE
|
Storage Range
|
-40° to 70°C
|
Operating Range
|
-20° to 60°C
|
Humidity
|
5-95%, RH non-condensing
|
Ingress Protection
|
IP32
|
DIMENSIONS AND WEIGHT
|
Dimensions
|
356 x 206 x 99 mm
|
Weight
|
4.0 Kg
|
61112301
|
WP -BCC Battery charger Control
|
|
|
|
|
|
|
|
|